Bakers Pride Oven VGH-Series Microwave Oven User Manual


 
Rotisserie Ventless Hood Maintenance
13
Cleaning the Grease Baffle
1. Shut down the unit.
2. Open the front Hood door and Filters door, and slide out the grease baffle from the unit.
3. Spray the grease baffle with degreasing type soap.
4. Rinse with hot water; dry, and replace in hood.
Replacing the Charcoal/Odor Filter
1. Shut down the unit.
2. Open the hood door and the filters door on the front of the unit by pulling out on the handles.
3. Slide the used filter out of the unit.
4. Remove the replacement filter from the plastic bag.
5. Observing the “AIR FLOW DIRECTION” mark on the filter, slide the filter into the unit.
When installing a new filter, slight resistance should be observed as the filter is
being slid into place. This resistance is generated by flap metal plates located on
the top of the filter compartment frames. If this resistance is not felt after a period
of time it may become necessary to adjust the pressure that these plates provide
by pulling them slightly downwards with your fingers.
6. Close the doors.