Bakers Pride Oven XSG Griddle User Manual


 
3
1.INSTALLATIONINSTRUCTIONS
A.SAFETYPRECAUTIONS
RETAINTHISMANUALFORFUTUREREFERENCE.
IMPORTANT:BeforeusingyourBaker'sPridegriddle,theprotectivecoatingthatwasappliedatthefactory
mustbecompletelyremovedwithacommercialde-greaser.Afterathroughcleaningapplyahigh
temperaturesaltfreefryingoilandyourunitisreadytouse.
B.UNPACKINGINSTRUCTIONS:
FORYOURSAFETY,THEFOLLOWINGSAFETYPRECAUTIONSSHOULDBEFOLLOWEDANDENFORCED.
IFYOUSMELLGAS:
·SHUTOFFGASSUPPLYTOAPPLIANCE
EXTINGUISHOPENFLAMES
·IMMEDIATELYCALLYOURGASSUPPLIER
1.Aseparategasshut-offvalveshouldbeinstalledinthegaslineaheadoftheunit,asrequiredbycodes.
2.LIGHTING:Followtheinstructionsonpage5.
3.Atleast24inchesmustbeprovidedatthefrontofunitforservicing.
4.Wheninstalling,neverenclosethebottomareaoftheunitwitharaisedcurborotherconstructionthatwould
obstructtheflowofairintotheunit.
5.Thisunitmaybeoperatedwith0(sideandback)minimumclearancetonon-combustibleconstruction
materials.
6.Thisinstallationmustconformtolocalcodes,orinabsenceoflocalcodestotheNationalFuelGasCodeANSI
Z223.1,latestedition.InCanadaitmustconformtocurrentNationalStandardCAN/CGAB149.1(natural
gas)orCAN/CGAB149.2(propane)InstallationCodeforGasBurningAppliances&Equipment.
7.Electricaldiagram(modelXSGonly)islocatedontherightsideoftheunit.
8.Theapplianceanditsindividualshut-offvalvemustbedisconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressuresinexcessof1/2psi(3.45kPa).
9.Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingitsindividualmanualshut-off
valveduringanypressuretestingofthegassupplypipingsystemattestpressuresequaltoorlessthan1/2”
psi(3.45kPa).
10.Thisappliancemustbeinstalledunderaventilationhood.
11.Donotobstructtheflowofcombustionandventilationair.
12.Theareaaroundthisoranyothergasappliancemustalwaysbekeptfreeandclearfromcombustibles.
Carefullyunpackthegriddleandinspectimmediatelyforshippingdamages.YourGriddlewasshippedina
cartondesignedtogivemaximumprotectioninnormalhandling.Itwasthoroughlyinspectedbeforeleavingthe
factoryandthecarrieracceptedandsignedforit.Fileanyclaimsforshippingdamageorirregularitieswiththecarrier.
C.GASCONNECTIONS
MAINSHUT-OFFVALVE
PRESSUREREGULATOR
FLUE
Figure“A”