Beko ASN541S Refrigerator User Manual


 
12 / 30 EN
Refrigerator / User Manual
Installation
3.12. Things to do to have
the filter usage time
calculated automatically
ASP341 models only
(For products connected to the mains water line
and equipped with filter)
1.
Plug in the refrigerator. Press A (key lock) button
simultaneously to enable the key lock.
A
3
4
2
1
2.
Then press on the following buttons in turn.
A
3
4
2
1
1.Vacation button
2.Fridge temperature setting button
3.Quick Cool setting button
4.Freezer temperature setting button
When the buttons are pressed in the correct order,
Key Lock symbol will turn off, buzzer will sound
shortly and Filter Change Warning indicator will
turn on. When the Filter Replacement Warning
button is pressed on, filter usage times are started
to be calculated automatically.
C
If the filter usage time is calculated
automatically, Filter Change Warning
indicator will illuminate continuously in a
few seconds after the product is plugged
in.
C
Automatic filter usage time calculation is
not enabled ex factory. It must be enabled
in products equipped with a filter.
C
If the same procedure is repeated when
the automatic filter usage time calculation
is enabled, then the function will be
cancelled.
3.13. Before starting to use
the water/ice dispenser
(This feature is optional)
• If the water pressure is below 1 bar then a
separate pump may need to be used.
• Water system of the refrigerator must be
connected to the cold water line. It must not be
connected to hot water line.
• No water may be obtained in the initial start-
up of the refrigerator. Because there is air in
the system. To discharge air from the system,
press dispenser latch for 1-2 minutes until
water comes from the dispenser. Water flow
may be irregular at the beginning. After the
air in the system is discharged, water flow will
return to normal.
• During initial use, you will have to wait
approximately 12 hours for the water to cool
down.
• It will take around 1-2 days for the system to
produce the full amount of ice.
• Water pressure must be between 1-8 bars for
the operation of ice/water dispenser smoothly.
For this, check that 1 glass of water (100 cc)
can be filled in 10 seconds.
• The first 10 glasses of water should not be
consumed.
• You must wait approximately 12 hours to
obtain ice from the ice dispenser for the first
time. If there is not enough ice in the ice
container, ice may not be obtained from ice
dispenser.