Beko HB60PX Ventilation Hood User Manual


 
- 5 -
ENGLISH
GB
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further reference. The appliance has
been designed for use in the ducting version (air exhaust to
the outside – Fig.1B), filtering version (air circulation on the
inside – Fig.1A) .
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the
air in the environment and use a fuel source other than
electrical energy, as the cooker hood removes the air from
the environment which a burner or fireplace need for
combustion. The negative pressure in the environment must
not exceed 4Pa (4x10-5 bar). Provide adequate ventilation
in the environment for a safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- check the data plate (positioned inside the appliance) to
ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- This device must be connected to the supply network
through either a plug fused 3A or hardwired to a 2 phase
spur protected by 3A fuse.
2. Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the appliance.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid leaving exposed flames and always ensure that
the burners are covered as open flames are damaging
for the filters and a fire hazard
E) Constantly check food frying to avoid overheated oil
becoming a fire hazard
F) Disconnect the electrical plug prior to any
maintenance.
G) This appliance is not intended for use by young
children or infirm persons without supervision
H) Young children should be supervised to ensure they
do not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions
This appliance conforms to the European Directive
EC/2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed of in
a suitable manner, the user is helping to prevent potential
damage to the environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling collection
point. Follow local guidelines when disposing of waste. For
more information on the treatment, re-use and recycling of
this product, please contact your local authority, domestic
waste collection service or the shop where the appliance
was purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out by
specialised personnel.
• Electrical Connection
The appliance has been manufactured as a class II, therefore
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the
network in the case of direct connection to the electrical
network.
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection
tube composed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the cooker
hood exhaust to the same conductor used to circulate hot air
or for evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s) (Fig.6)
so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
We recommend the use of an air exhaust pipe with a
diameter of 150. If a pipe with a smaller diameter is used, the
efficiency of the product may be reduced and its operation
may become noisier
If your appliance has been designed for use in habitations
supplied with acentralised suction device perform the
following operations:
-The switch controls opening and closure of a valve using
a thermoelectical device. By placing the switch in the ON
position, after a minute, the valve opens rotating 90° allow-
ing suction of the stale air. By placing the switch in the OFF
position, the valve closes after 100 seconds.