Beko HBV60X Ventilation Hood User Manual


 
ENGLISH
GB
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further reference. The appliance has
been designed for use in the ducting version (air exhaust to
the outside – Fig.1B), filtering version (air circulation on the
inside – Fig.1A) or with external motor (Fig.1C).
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultane-
ously with an open fireplace or burner that depend on the air
in the environment and use a fuel source other than electrical
energy, as the cooker hood removes the air from the environ-
ment which a burner or fireplace need for combustion. The
negative pressure in the environment must not exceed 4Pa
(4x10-5 bar). Provide adequate ventilation in the environment
for a safe operation of the cooker hood.Follow the local laws
applicable for external air evacuation.
Before connecting the model to the electricity network:
- check the data plate (positioned inside the appliance) to as-
certain that the voltage and power correspond to the network
and the socket is suitable. If in doubt ask a qualified electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- This device must be hardwired to the mains supply network
by connecting to a single phase spur protected by 3A fuse.
2. Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating.
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the appliance.
C) Flambè cooking is prohibited underneath the cooker
hood.
D) Avoid leaving exposed flames and always ensure that
the burners are covered as open flames are damaging for
the filters and a fire hazard.
E) Constantly check food frying to avoid overheated oil
becoming a fire hazard.
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young children
or infirm persons without supervision.
H) Young children should be supervised to ensure they
do not play with the appliance.
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions.
This appliance conforms to the European Directive
EC/2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed of in
a suitable manner, the user is helping to prevent potential
damage to the environment or to public health.
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling collection
point. Follow local guidelines when disposing of waste. For
more information on the treatment, re-use and recycling of
this product, please contact your local authority, domestic
waste collection service or the shop where the appliance was
purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out by
specialised personnel.
• Electrical Connection
The appliance has been manufactured as a class II, therefore
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indi-
cated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the net-
work in the case of direct connection to the electrical network.
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection
tube composed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the cooker
hood exhaust to the same conductor used to circulate hot air
or for evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s) (Fig.6)
so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with a
smaller diameter is used, the eciency of the product may be
reduced and its operation may become noisier.
• Warning: if the bulbs are not working, ensure that they are
screwed in fully.
Installation
Prior to proceeding with the assembly operations (according
to the model that you have purchased), to facilitate handling
of the device, remove the grille as indicated in Fig. 5.
The appliance is equipped with 2 air outlets, to be used in
accordance with your specic requirements: one is located on
the upper part of the appliance and the other at the rear (Fig.
1A). The ange D, to which the air exhaust pipe is connected,
and a plug B, used to shut o the unused air outlet, are both
- 6 -