5
Warning: This hood is designed for domestic use only.
When used in the extraction mode the cooker hood ducting must not be connected to a
flue which is used for exhausting fumes from appliances supplied with energy other than
electric, such as a central heating flue or a water heater flue.
If the room where the cooker hood is to be used contains a fuel burning appliance such as
a central heating boiler, then its flue must be of the room sealed or balanced flue type. If
other types of flue or appliances are fitted, ensure there is adequate ventilation in the
room.
All installations must comply with local authority requirements for the discharge of exhaust
air.
• Positioning
When installed above a cooking appliance the distance between the surface of the
appliance hotplate and the lower grill of the hood must not be less than 65cm (25½”).
This appliance is suitable for ceiling heights of approximately 225cm (7’5”) and 262cm
(8’7”) depending on the installation. If you have a ceiling greater than this height please
ring our spares department on 0
844 815 3745 for the tall ceiling kit (see Optional Extras).
Do not fit above a cooker with a high level grill.
The distance between adjoining wall cabinets and the worktop must not be less than
40cm (15¾”).
If the cooker hood is installed for use above a gas appliance then the provision for
ventilation must be in accordance with the Gas Safety (Installation and Use) Regulations
and the relevant building regulations.
Warning: The fan motor of this cooker hood incorporates a thermal cut-out which will
operate if the cooker hood is installed below the minimum recommended height or the
motor overheats. If the cut-out operates. Switch off the cooker hood and allow the motor
to cool, the cutout will then reset itself.
• Unpacking
Care should be taken when unpacking the cooker hood to ensure that the outlet flange,
screws and wall plugs, literature pack etc. are retained with the hood.
- Components
The hood consists of :
1 hood body complete with controls and lights
1 complete telescopic flue
1 connecting flange Y.
1 bracket Z to fix the flue unit to the wall
1 bag containing screws and documents