Glen Dimplex Home Appliances Ltd DIH900 Ventilation Hood User Manual


 
7
1A) LUMINOUS
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes
The “Automatic stop timer” allows the hood to continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
1B) MECHANICAL
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
G= MOTOR WORKING indicator
Good functioning of the hood depends on the regularity with which maintenance
operations are carried out, in particular of the anti-grease filters and the activated
charcoal filter. The anti-grease filters have the function of holding back grease
particles suspended in the air, and are thus subject to clogging with time depending on
the frequency of use of the appliance.
Clean the filters every 2 months, carrying out the following operations:
- Remove the filters from the hood and wash them with warm soapy water.
- Rinse in abundant lukewarm water and leave them to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may be subject to colour alterations due to many washes. This
is natural over time and will not affect the performance of the appliance.
In case of inobservance of the washing instructions there is a risk of the filter catching
fire.
Frequently clean off all the deposits on the fan and other surfaces, using warm soapy
water.
Replacement of the Halogen Lamp
WARNING!! DISCONNECT FROM MAINS BEFORE CHANGING LAMP
Note: The bulb is not covered by the guarantee as it is a consumable item.
Lamps are available from our spares department, please ring 0
844 815 3745 and
quote part no.CHT265B
To replace the halogen lamp, carefully prise off the cover and remove complete with the
lamp glass.
Put in the new lamp taking care not to touch the glass with fingers and replace lamp
glass and cover.
Do’s and Don’ts
Do take extra care when frying
Do clean grease filters and hood regularly