Glen Dimplex Home Appliances Ltd FS 60 DO DF Oven User Manual


 
Data badge
On the bottom of the front frame behind
the oven door.
Type of gas
This cooker must only be used with Natural
Gas only, as specified on the appliance
data badge.
Gas category
Natural Gas - I
2H
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point
Use the oven injector
Aeration - Fixed
Electrical supply/Load
220 - 240V ~ 50Hz
3290 - 3915W
Spark generator: Mains operated 6 outlet
controlled by a single rocker switch at the
LHS of the facia to individual electrodes. 2
outlets shorted to earth.
Warning: This cooker must be earthed.
Hob - Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Countries of destination
GB - Great Britain, IE - Ireland
26
Fuel Burner / Element Nominal Injector
Rate Qn Size
Natural Hob - LHF 1.0kW 77
Gas Hob - LHR & RHR 2.0kW 104
Hob - RHF 3.0kW 129
Total heat input 8.0kW -
TECHNICAL DATA