Bertazzoni A304GGVXT Range User Manual


 
21
Models
A304GGVXE [M7S0GNA4X(2,5)AUG]
A304GGVXT [M7S0GNU4X(2,5)AUA]
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Rear L 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Front R 1,18 NG 4” 6100 1787 1500 439 Regulated
0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 1,85 NG 4” 14500 4248 3500 1025 Regulated
downside 1,10 LP (Propane) 11” 14500 4248 3500 1025 0,54
Broiler Oven 1,70 NG 4” 12000 3516 Only Max Only Max No by-pass
upside 0,98 LP (Propane) 11” 12000 3516 Only Max Only Max No by-pass