Models CB36600X [C3Y0..U7X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,92 NG 4” 3750 1098 900 264 Regulated
0,56 LP (Propane) 11” 3750 1098 900 264 0,29
Semi-Rapid Rear L & C 1,17 NG 4” 6000 1759 1500 439 Regulated
Front C 0,73 LP (Propane) 11” 6300 1845 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 2046 2500 732 Regulated
0,98 LP (Propane) 11” 11400 3339 2500 732 0,47
Front L Inner 0,80 NG 4” 2730 799 900 264 Regulated
Dual Burner 0,50 LP (Propane) 11” 2900 8479 900 264 0,29
Front L Outer N°2 x 1,30 NG 4” 15000 4394 4500 1319 Regulated
N°2 x 0,83 LP (Propane) 11” 16400 4804 4500 1319 0,65
Models CB36500X [C3W0..U7X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] Diam. [mm]
Auxiliary Front R 0,92 NG 4” 3750 1098 900 264 Regulated
0,56 LP (Propane) 11” 3750 1098 900 264 0,29
Semi-Rapid Rear L and R 1,17 NG 4” 6000 1759 1500 439 Regulated
0,73 LP (Propane) 11” 6300 1845 1500 439 0,36
Rapid Front L 1,55 NG 4” 10400 2046 2500 732 Regulated
0,98 LP (Propane) 11” 11400 3339 2500 732 0,47
Centre Inner 0,80 NG 4” 2730 799 900 264 Regulated
Dual Burner 0,50 LP (Propane) 11” 2900 8479 900 264 0,29
Centre Outer N°2 x 1,30 NG 4” 15000 4394 4500 1319 Regulated
N°2 x 0,83 LP (Propane) 11” 16400 4804 4500 1319 0,65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body
and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4) Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with
liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always
operates at maximum and therefore no minimum adjustment is required.