Bertazzoni H304GGVVI Range User Manual


 
9
COOKER HOOD INSTALLATION
The bottom of the hood should be 25
1/2" (65 cm) min. to 31 1/2" (80 cm) above the countertop. This would
typically result in the bottom of the hood being 61
1/2" (156.2 cm) to 67 1/2" (171.5 cm) above the floor. Check
for other minimum clearance requirements mandated by specific local or regional installation codes. Refer to
the rangehood installation instructions for additional information. These dimensions provide for safe and
efficient operation of the hood.
ELECTRICAL CONNECTION
This unit is manufactured for a polarized, grounded 120 VAC/60 Hz, 15A 3 pin-earthed receptacle. Electric
power consumption is about 150 W. The minimum of 102 VAC is required for proper operation of gas ignition
systems. This circuit must be grounded and properly polarized. The unit is equipped witth a SJT power cord.
In case of replacement, the cable shall be replaced with one of the same type, size and length.
WARNING
Cooling fan failure.
In case of a cooling fan failure the frontal red indicator "Fan Failure" will light up. If this happens, please turn
off the appliance immediately, call the nearest after sale assistance service center and do not use the
appliance until the cooling fan system of the appliance has been properly repaired by a qualified technician.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong plug for your protection against shock hazard and should be
plugged directly into a properly grounded socket. Do not cut or remove the grounding prong from this plug.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit breaker box or fuse box before installing the gas cooker
Electrically ground gas cooker
Use copper conductors only. Failure to follow these instructions could resul in serious injury or death