14
Models H366GGV [M3Y0GTV4(L,N,D)(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Rear L & C 1,18 NG 4” 6100 1787 1500 439 Regulated
Front C 0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 2,00 NG 4” 16000 4688 4000 1172 Regulated
downside 1,15 LP (Propane) 11” 16000 4688 4000 1172 0,60
Broiler Oven 1,90 NG 4” 14500 4248 Only Max Only Max No by-pass
upside 1,10 LP (Propane) 11” 14500 4248 Only Max Only Max No by-pass
Models H365GGV [M3W0GTV4(L,N,D)(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Rear L and R 1,18 NG 4” 6100 1787 1500 439 Regulated
0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Front L 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Centre Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Centre Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 2,00 NG 4” 16000 4688 4000 1172 Regulated
downside 1,15 LP (Propane) 11” 16000 4688 4000 1172 0,60
Broiler Oven 1,90 NG 4” 14500 4248 Only Max Only Max No by-pass
upside 1,10 LP (Propane) 11” 14500 4248 Only Max Only Max No by-pass
CAUTION: save the orifices removed from the appliance for future use
REGULATION OF BURNERS
Primary air adjustment:
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1) Remove the oven bottom.
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 13) according to the measurements indicated in
table 4.
Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone
(Fig. 14) according to the measurements indicated in table 4.
TABLE N°4: Burner primary air regulation (indicative)
Burner
Type of gas Oven Broiler
Inches (mm) Inches (mm)
NG (Natural Gas) 6/16 (9) fully open
LP (Propane Gas) 1/2 (13) fully open