Follow the instructions below to change the oven burner nozzle:
1) Remove the oven level (Fig. 9).
2) Loosen the screw V and pull out the burner from the support being careful not to damage the ignition plug and the
thermocouple (Fig. 10).
3) Unscrew the nozzle R (Fig. 10) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas
according to what is indicated in Table below
4) Re-install all the parts in revers sequence from 3 to 1
(Fig. 9) (Fig. 10)
Follow the instructions below to change the broiler burner nozzle:
1) Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the
thermocouple (Fig. 11).
2) Unscrew the nozzle R (Fig. 11) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas
according to what is indicated in Table below.
Models X244GGVX [MLS0GTU4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Rear L 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Front R 1,18 NG 4” 6100 1787 1500 439 Regulated
0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 1,60 NG 4” 11000 3223 2400 703 Regulated
downside 0,95 LP (Propane) 11” 11000 3223 2400 703 0,48
Broiler Oven 1,50 NG 4” 10000 2930 Only Max Only Max No by-pass
upside 0,90 LP (Propane) 11” 10000 2930 Only Max Only Max No by-pass
CAUTION: save the orifices removed from the appliance for future use