Bertazzoni X)486GPIRX Range User Manual


 
9
BEFORE INSTALLATION
This appliance shall only be installed by an
authorized professional.
This appliance shall be installed in accordance
with the manufacturer’s installation instructions.
This appliance must be installed in accordance
with the norms & standards of the country where
it will be installed. The installation of this
appliance must conform to local codes and
ordinances. In the absence of local codes,
Installations must conforms to American National
Standards, National Fuel Gas Code ANSI Z223.1 –
latest edition** or B149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexible connector when moving the appliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properly installed in order to be accessible when
the appliance is installed in its final location. The
pressure regulator must be set for the type of gas
to be used. The pressure regulator has ½” female
pipe thread. The appropriate fitting must be
determined based on the size of your gas supply
line, the flexible metal connector and the shutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than ½ psi (3.5 kPa).
All opening and holes in the wall and floor, back
and under the appliance shall be sealed before
installation of the appliance.
A manual valve shall be installed in an accessible
location in the gas line external to the appliance
for the purpose of turning on or shutting off gas
to the appliance
WARNING!
Do not use aerosol sprays in the vicinity of this
appliance while it is in operation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operation may affect other vented appliances; in
each case it shall be installed in conformity with
the appropriate national and local standards.
TYPE OF GAS
This appliance is shipped from the factory for use
with natural gas. For use with propane LP gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedure is also included with each set of LP gas
nozzles.
GAS PRESSURE
The maximum inlet gas supply pressure incoming
to the gas appliance pressure regulator is 20’’
water column (5 kPa) .
The minimum gas supply pressure for checking
the regulator setting shall be at least 1“ w.c. (249
Pa) above the inlet specified manifold pressure to
the appliance (this operating pressure is 4” w.c.
(1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa
for LP Gas).