9
Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Rear L & C 1,18 NG 4” 6100 1787 1500 439 Regulated
Front C 0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear L 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Models C36500X (Z36 5 00 X) [C3W0..U4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] Diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Rear L and R 1,18 NG 4” 6100 1787 1500 439 Regulated
0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear L 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Centre Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Centre Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body
and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with
liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always
operates at maximum and therefore no minimum adjustment is required.