Best IS170 Ventilation Hood User Manual


 
- 10 -
MOUNT HOOD TO SUPPORT
FRAME
1. Install the hood to support frame by (6)
mounting screws (3.9x9.5mm), minding
that the controls are on the proper side.
2. Make electrical connections (refer to the
section “WIRING”).
3. Remove the two temporary fixing screws
of the lower flue and set it in place on the
hood.
MOUNTING
SCREWS
(3.9X9.5MM)
WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wiring
box with an appropriate connector.
3. Make electrical connections. Connect
white to white, black to black and green to
green.
4. Replace wiring box cover and screws.
Make sure that wires are not pinched
between cover and box.
WIRING BOX
COVER
NON-DUCTED
RECIRCULATION FILTER
INSTALLATION
1. Purchase a charcoal filter (FILTER
SQUARE - cod.B03300488) from your
dealer.
2. Install the charcoal filter by pressing the 2
tabs on the filter down into the special
housing and rotating upward.
CHARCOAL
FILTER