BEST BY BROAN P.O. BOX 140 HARTFORD, WISCONSIN 53027
K273 SERIES WIRING
K273 SERIES MOUNTING
120 VOLT 60 HZ GROUNDED WALL OUTLET
OFFSET FROM DUCT CENTER LINE
(STAY WITHIN 8” DIMENSION)
30” - 36”
L
L
C
10 "
13
16
FRAMING BEHIND
WOOD CROSS
SUPPORT
WOOD CROSS SUPPORT –
SECURED TO FRAMING AND
LOCATED BEHIND DRYWALL
DRYWALL
MOUNTING BRACKET
LOCATION
(ABOVE 36” HIGH
COOKTOP)
NOTE: Minimum hood distance above
cooktop must not be less than 24”.
A maximum of 30” above the cooktop is
highly recommended for best capture of
cooking impurities.
Distances over 30” above the cooktop
are at the installer’s and user’s
discretion - providing that ceiling height
and flue length permit.
CEILING
HOOD DISTANCE ABOVE 36” HIGH COOKTOP (SEE NOTE AT RIGHT)
HEIGHT
24” 25” 26” 27” 28” 29” 30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET 27-3/4” 28-3/4” 29-3/4”
9 FEET 27-3/4” 28-3/4” 29-3/4” 30-3/4” 31-3/4” 32-3/4” 33-3/4”
10 FEET WITH
30-3/4” 31-3/4” 32-3/4” 33-3/4”
FEXTK273
CENTER LINE OF
HOOD & DUCT
8”