FUSE REPLACEMENT
IF LIGHTS FAIL TO OPERATE, DISCONNECT
POWER AT THE SERVICE ENTRANCE. CHECK
THE FUSE AND REPLACE IF NECESSARY.
1.Remove the grease filter and pull the visor open.
2.Locate the fuse holder on the top right hand side
of the light housing.
3.Unscrew the fuse holder cap and remove the
fuse.
4.Replace the fuse with the same size and
amperage (5 x 20mm, 4 amp, 125 volt).
DO NOT use fuses greater than 4 Amps. Fuses
greater than 4 Amps may damage the
transformer.
5.Reinstall the fuse cap and grease filter.
6.Reconnect power at the service entrance.
HALOGEN BULBS
This range hood requires two halogen bulbs (Type
T3, 12Volt, 20Watt Max, G-4 Base).
WARNING: Always switch off the
electricity supply before carrying out any
operations on the appliance.
To change bulbs:
1. Open the cover by prying from the proper slots.
- DO NOT ROTATE.
CAUTION: Bulb may be hot.
2. Replace with a Type T3, 12Volt, 20Watt Max,
G-4 Base bulb. Do not touch replacement bulb
with bare hands!
DO NOT use bulbs greater than 20 Watts.
Bulbs greater than 20 Watts will cause the
fuse to open.
!