Bi-pin Florescent Lamp Installation / Verification
(Only Glass Door Models)
Prior to applying power to the unit, verify that all lamps are properly installed and fully engaged in
the lamp holders.
Proper lamp engagement is achieved by rotating the lamp 90 degree from its insertion position
until it snaps or clicks into place.
Visual verification can be made on units without safety shields by using the identification mark on
the end of the bulb. Properly installed bulbs will have the mark centered between the halves of
the lamp holder.
On units with shields, the identification mark cannot be seen. Physically verify that the lamp has
been rotated and locked into place.
See pictures below.
Caution: Improperly installed lamps may cause damage to the lighting circuit.
Beverage-Air shall have no liability whatsoever for equipment or component failures or other
damages or losses which arise as a result of improper installation of lamps.
Bi-pin lamp end Properly installed lamp without shield. Verify identification mark identification mark is positioned as
shown.
Properly installed lamp with shield. Improperly installed lamp with shield.
Requires physical verification that lamp has Note that pins have not achieved full 90… rotation
been rotated and locked into place .