Installation
10
Electrical Connections
All Models
NOTE: Electrical connections must be performed
by a qualified installer only.
Before making any el ectri cal c o nnectio ns to these
appli ances, check that the power supply is ade-
quate f or the vo l tage, amperage, and phase require-
ments stated on the rating name plate mounted on
the appliance.
The circuit breaker that is used to provide power
to this appliance must have a minimum of .076”
(3mm) contact spacing. The circuit breaker must
meet all Local and National installation standards.
All appliances must be installed in accordance
with Local or National Electrical codes.
A wiring schematic is located on the inside of the
removeable side panel.
NOTE: Disconnect the power supply to the ap-
pliancebeforeservicing.
WARNING!!
Improper installation will invalidate your
warranty.
Electric Models
A strain relief for the power supply cord is required.
The installer must suppl y a cord bushi ng that meets
all Local and Nati o nal i nstal l atio n standards.
Gas Models
U.S. and Canadian Installations
A pow er cord (115V or 230V) is supplied with a
plug attached. Plug the power cord into the de-
sired receptacle.
Export Installations
A 230V 13 amp fused power cord is supplied with
a plug attached. Plug the power cord into the ap-
propriate receptacle.
See Figure 8 for power cord routing and connec-
tions to the line filter.
WARNING!!
If the supply cord is damaged, it must be
replaced by a special cord or assembly
available from the manufactureror its ser-
vice agent.
Power Connections
Line Filter
Line Filter
Mounting Bracket
Power Cord with
13 amp fuse
Strain Relief
Rear view of BC14G
with rear panel removed
L 1 ---
Brown wire
N ---
Blue wire
Ground Symbol ---
Green/Yellow wire
Line Filter
Export Installations
Figure 8