Blodgett KLS-20G Hot Beverage Maker User Manual


 
13
4.0 OPERATION (Continued)
SPARK IGNITER FAILURE:
In the event the spark igniter module fails the unit may still be operated by carefully following
these instructions.
1. Turn thermostat to OFF position; completely counterclockwise.
2. Turn power switch to OFF position.
3. WAIT A MINIMUM OF 5 MINUTES BEFORE PROCEEDING.
4. Turn dial on combination control to ON position (if not already on).
5. Turn power switch to ON position.
6. Wait two minutes and ten seconds and then immediately light pilot with long match or taper.
7. After 10 - 15 seconds gas valve will allow main burner gas to flow when thermostat is turned
on.
8. The pilot will now stay ignited as long as the power switch remains ON. If power switch is
turned OFF, repeat the above instructions. It is intended that the unit be operated in this
manner only in emergency situations and only while it is attended (do not leave pilot lit
overnight; shut off power switch). A qualified serviceman must be called promptly.