Bloomfield 1040 Coffeemaker User Manual


 
SERVICING INSTRUCTIONS
CAUTION
Electric Shock
Hazard
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermo probe,
heating elements, brew circuit tubing, faucet valve and piping.
Top panel is held by two screws at the rear and a retaining lip at
the front.
FRONT PANEL:
Upper front panel is held by two screws at the bottom and a
retaining lip at the top. Lower panels are held by retaining clips
under the warmer plates.
Remove front panel to access controller and power board.
Solenoid on Models 1040 & 1072 are accessible through the
front panel.
WARMER ELEMENTS:
Warmer plates screw to the bracket, and are locked by a nut from
below. For lower warmers, remove the appropriate hole plug to
access the nut. For top panel warmers, remove the top panel to
access the nut. Remove the warmer plate to access the warmer
element.
Fig. 13 Access Panels