Bloomfield 1091 Coffeemaker User Manual


 
7. Set the tanks back into the brewer. Reassemble the tank lid
to the tanks. Make sure the gasket is properly in place, then
reinstall the hold-down strap.
8. Reinstall wiring to heating elements and controller Reinstall
the hi-limit thermostat (if removed). For right side,
reassemble piping for the faucet. Verify that all internal
components are dry, then reinstall the top panel.
10. Reconnect brewer to electrical supply and reconnect water
supply.
11. Install the brew chambers without filter papers or grounds.
Run at least three full brew cycles and discard all water
generated.
12. Brewer is ready to use.
NOTE: Normally, silicone
hoses do not need to be
delimed. Should deliming
hoses become necessary,
Bloomfield recommends
replacing the hoses.
SERVICING INSTRUCTIONS (continued)
21
645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer