Bloomfield 1092 Coffeemaker User Manual


 
INSTALLATION INSTRUCTIONS (continued)
NOTE: This equipment must be
installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT: Do not connect
brewer to electrical power until
the tank is filled with water.
Pour water into the pour-over
opening until water flows from
the brew head.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
In some areas, local codes require a backflow preventer (check
valve) to be installed on the inlet water line. If a backflow
preventer is used, you must install a water hammer arrester in
the incoming line, between the backflow preventer and the
brewer inlet, as far away from the brewer as space will allow.
This will relieve the excessive back pressures that can cause
faucet leaks and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Brewers must be wired by an electrician, and require a dedicated
115/230V or 120/240V 20A circuit (50/60 Hz, L1, L2, Neutral,
plus ground). Remove front panel to gain access to terminal
block. Green terminal must be connected to a suitable building
ground. Circuit must be capable of 4000 Watts (model 1090 and
1092) or 7000 Watts (model 1091 and 1093).
See figure 3 at right.
IMPORTANT: Wiring must be installed in approved solid or
flexible conduit, and must be secured to the brewer with a strain
relief (to be provided by the installer).
Fig. 3 115/240V Terminal Block
5
Fig. 2 Water Supply Installation
645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer