Bloomfield 2016 Coffeemaker User Manual


 
INSTALLATION INSTRUCTIONS (continued)
NOTE: This equipment must
be installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING ELECTRIC
SHOCK HAZARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT: Do not attempt to
override the automatic tank fill
feature which requires that the
tank must be full of water to
start operations. Any attempt to
override this feature will void
the warranty.
IMPORTANT:
Before connecting to electricity,
make sure the E-Max™ has
been properly connected to the
water supply.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
For ‘Filter-Ready” units, refer to filter installation and hook-up
instructions packed with the brewer.
5. NSF requires that the brewer be able to be moved for
cleaning underneath. A flex line or loops of copper tubing
will satisfy this requirement.
6. In some areas, local codes require a backflow preventer
(check valve) to be installed on the inlet water line. If a back
flow preventer is used, you must install a water hammer
arrester in the incoming line, between the backflow
preventer and the brewer inlet, as far away from the brewer
as space will allow. This will relieve the excessive back
pressures that can cause faucet leaks and solenoid
malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
NOTE: Models 2012 & 2072 require a 115 - 125 V 15A circuit
(50/60 Hz, 2 wire plus earth ground, with
NEMA 5-15R or 5-20R Receptacle)
Models 2016 & 2074 require a 120/240V 20A circuit
(50/60 Hz, 2 hot legs / 1 neutral leg, plus earth ground).
Circuit must be capable of 3500 Watts.
This brewer is and
listed under UL file E9253.
This brewer meets
Standard 4 only when installed,
operated and maintained in accordance with the enclosed
instructions.
AGENCY LISTING INFORMATION
E9253
E9253
STD 4
SHUT-OFF VALVE
(PROVIDED BY
PLUMBER)
COPPER LOOPS OR FLEX LINES
(PROVIDED BY PLUMBER)
WATER
SUPPL
Y
FLOW
SOLENOID
STRAINER
WASHER
5