Bloomfield 8372 Coffeemaker User Manual


 
11
SERVICING INSTRUCTIONS
ACCESS PANELS
Top panel is held by four screws at the corners.
Front panel is held by two clips under each warmer plate, three
screws at the bottom and a retaining lip at the top.
Top rear panel is held by two clips under the warmer plate.
TEMPERATURE ADJUSTMENT
With the “READY TO BREW” light ON, draw a cup of water from
the hot water faucet. Check the temperature of the water with a
thermometer of known accuracy.
If temperature adjustment is necessary, remove water bottle and
top panel.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on
altitude.
Upon completion, reinstall top panel.
CAUTION
Electric Shock
Hazard
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
NOTE:
Each warmer plate has a center
stud which screws into a
bracket. Warmer plates on
Canadian brewers are secured
with a nut. Remove button plug
on bottom of brewer to access
nut on warmer plate. Remove
warmer plates by turning
counter-clockwise.
NOTE:
Optimum brewing temperature
range is 195ºF to 205ºF (90ºC
to 96ºC).
IMPORTANT:
A mechanical thermostat will
maintain temperature within
±5ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF.
Fig. 8 Access Panels
Table 1 Boiling Temperature by Altitude