Bloomfield 8742 Coffeemaker User Manual


 
SERVICING INSTRUCTIONS (continued)
REPLACE HEATING ELEMENT
Remove tank cover assembly (see page 13).
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn water
supply OFF.
Remove top panel.
Disconnect wiring from solenoid.
Unscrew water inlet piping from solenoid.
Remove two screws holding solenoid to bracket.
Remove brew and dilution manifold from solenoid, transfer
components to new solenoid
Transfer solenoid bracket to new solenoid.
Reassemble in reverse order.
REPLACE TIMER ASSEMBLY
Unplug power cord or turn circuit breaker OFF.
Remove top panel. Remove knob and three screws holding timer
to bracket. Disconnect wiring to timer.
Reassemble in reverse order.
Adjust timer as described on page 13
CLEAN STRAINER SCREEN
Unplug power cord or turn circuit breaker OFF. Turn water
supply OFF.
Remove bottom cap from strainer. Withdraw filter screen from
strainer body.
Clean screen with a suitable brush.
Reassemble in reverse order.
IMPORTANT: When replacing
heating element, also replace
seal gaskets.
14
Fig. 12 Water Line Strainer
606 Owners Manual for 8742-8748 Tea Brewer 76116