Bloomfield WVG-136RWT Griddle User Manual


 
WARRANTY ................................................................ xi
SPECIFICATIONS ....................................................... 1
FEATURES & OPERATING CONTROLS ................... 2
PRECAUTIONS & GENERAL INFORMATION ........... 6
AGENCY LISTING INFORMATION ............................ 7
INSTALLATION ........................................................... 8
OPERATION ................................................................ 12
CLEANING INSTRUCTIONS ....................................... 17
MAINTENANCE SCHEDULES .................................... 19
MSDS (Ansulex Low pH) ............................................. 24
TROUBLESHOOTING SUGGESTIONS ..................... 26
PARTS & SERVICE ..................................................... 27
CUSTOMER SERVICE DATA ..................................... 25
Thank You for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that
it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for
the appliance in a manner which will ensure its optimum performance.
This manual applies to the following Wells Bloomfield models:
WVG-136
WVG-136RW
WVG-136RWT
TABLE OF CONTENTS
SPECIFICATIONS
INTRODUCTION
1
502 p/n 304986 OpM WVG-136 Ventless Griddle
MODEL
ROLL
WARMER
VOLTS
50/60 Hz
3ø AMPS
AMP
S
WATTS
DIMENSIONS
POWER CORD
L1 L2 L3
WVG-136 NO
208V 17 29 17 35 7,300
240V 20 33 20 40 9,500
WVG-136RW
WVG-136RWT
YES
208V 20 28 20 38 7,900
240V 24 33 24 43 10,400
30-3/8” WIDE
(42-3/8" wide including spacers)
77-1/4” HIGH
35-1/2” DEEP
Power Cord (when provided):
NEMA 15-60P
BACK SIDE BOTTOM TOP
inches n/a 6 6 19
millimeters n/a 152 152 483
Minimum clearances required from unit to nearest combustible surface or object