Prior to installation
The extractor hood may be connected to
correctly installed earthed sockets only.
Preferably attach the earthed sockets
directly behind the flue duct.
NOTE:
An additional earthed socket is required for
connecting the screen to the power supply.
The earthed socket should be
connected via its own circuit.
If the earthed socket is no longer
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
1
/
8
” and interrupts all poles. Such devices
include circuit breakers and contactors.
CAUTION:
If the connecting cable for this appliance is
damaged, the cable must be replaced by
the manufacturer or his customer service
or a similarly qualified person in order to
prevent serious injury to the user.
Electrical data:
Are to be found on the name plate inside
the appliance after removal of the filter
frame.
WARNING: Before undertaking any
repairs, always disconnect the extractor
hood from the electricity supply.
Length of the connecting cable: 51
1
/
8
”.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
Electrical connection
WARNING: THIS APPLIANCE MUST
BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow Earth
Blue Neutral
Brown Live
If you fit your own plug, the colours of these
wires may not correspond with the identify-
ing marks on the plug terminals.
This is what you have to do:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or coloured
green or green and yellow.
2. Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or
coloured white.
3. Connect the brown (Live) wire to the
terminal marked ‘L’, or coloured black.
Electrical connection
Preparing the ceiling
The ceiling must be flat and horizontal.
Ensure that the ceiling is capable of pro-
viding a firm hold for mounting screws
and plugs. The enclosed plugs are sui-
table for concrete and stonework. If the
ceiling is made of any other material,
use appropriate mounting components.
Weight in kg: 40,5.
We reserve the right to construction changes within the