5) Hang the Hood Place the hood by sliding the round mounting holes in the top of the hood over the
top hood screws. Check and adjust for level. Tighten the screws
Install two lower hood screws from underneath.
6) Connect to Ductwork Connect hood to ductwork in house.
7) Connect Electric Plug electrical cord into grounded outlet. Note: The hood requires a 120V AC,
60Hz., 15A Branch Circuit.
8) Install Chimney Remove protective film from both sections of chimney.
Connect the sections, one inside the other. For recirculation, the slots in the upper
chimney section should be at the end closest to the ceiling. When venting to the
outside, the top section can be turned upside down to conceal the vents.
Figure 5: Hang the Hood
Figure 6: Install Lower Hood Screws
1/4" (6 mm)