Instructions for the installer
21
2. POSITIONING OF HOB
The following operation requires building and/or carpentry work so must
be carried out by a competent tradesman.
Installation can be carried out on various materials such as masonry,
metal, solid wood or plastic laminated wood as long as they are heat
resistant (T 90°C).
2.1.1 Attachment to support structure
Create an opening with the
dimensions shown in the figure in the
top surface of the counter, keeping a
minimum distance of 50 mm from
the rear border.
This device is classified "type Y" as
regards risks against fire and it can
be set adjacent to walls that are
higher than the work surface,
provided that a distance of 145 mm.
is respected (as shown in the figure)
to prevent damage due to
overheating.
Make sure there is a minimum of 750 mm between the hot plate flames
and any shelf that may be installed directly above them.
Carefully position the insulation gasket (supplied) on the external
perimeter of the hole made in the top surface (see figures below) and try
to make it stick to the entire surface by applying light pressure with your
hands. Refer to the coordinates shown in the figure, bearing in mind that
sides A should be adjacent to the hole. Secure the hob to the counter
with brackets B (supplied). Carefully trim any excess from border C of the
gasket. The distances in the following drawing refer to the hole on the
inner side of the gasket.