Bosch Appliances SHE990 Dishwasher User Manual


 
Figure 28
Figure 29
Casing
Electrical Connection
ELECTFiICAL CONNECTmON
Electrical Shock Hazard
To avoid ebctricaJ shock, do not work on an
energized circuit. Doing so could result in serious
injury or death. OnJy quaJified eJectricians shouJd
perform ebctrical work. Do not attempt any work
on the dishwasher electric suppJy circuit until you
are certain the circuit is de-energized.
Fire Hazard
To avoid a fire hazard, make sure eJectricaJ work
is properly installed. Only qualified electricians
shouJd perform electricaJ work.
Grounding instructions
The dishwasher must be properly grounded before
operating, This appliance must be connected to a
grounded metal permanent wiring system, or an
equipment grounding conductor must be run with the
circuit conductors and connected to the equipment
grounding terminal or lead on the dishwasher, Make sure
that the dishwasher is connected to a suitable ground in
compliance with all local codes or, in the absence of a
local code, with the NATIONAL ELECTRICAL CODE in
the United States or the CANADIAN ELECTRIC CODE
C22,1-latest edition in Canada as well as any provincial/
state or municipal or local codes that apply,
1 Retrieve the strain relief plate, and install a strain relief
(not supplied) into the opening on the strain relief plate,
NOTE: Orient the strain relief as shown in Figure 28,
2 Pass the electrical supply cable through the strain
relief, as shown in Figure 29, Make sure the outer wire
casing extends about 1/2" (13mm) through the strain
relief,
3 Tighten the strain relief screws,
4 Slide the strain relief plate into the junction box, and
secure it to the junction box with the supplied screw,
13