PowerBOSS™ 5000W Portable Generator OPERATION
RECEPTACLES
120 Volt AC, 20 Amp, Duplex
Receptacles
Each of these outlets (Figure 5) is protected against
overload by a push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
120 Volt AC, 15 Amp Duplex
Receptacle
Each of these outlets is protected against overload by a
push–to–reset circuit breaker (Figure 6).
Use each outlet to operate 120 Volt, 60 Hz, single phase
loads requiring 1,800 (1.8 kW) watts at 15 Amps of
current.
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See “Don’t Overload
Generator”.
Receptacles may be marked with rating value greater
than generator output capacity.
CAUTION
Figure 5 — 120 Volt, 20 Amp Duplex Receptacle
Figure 6 — 120 Volt AC, 15 Amp Duplex Receptacle