Broan 356NDK Ventilation Hood User Manual


 
INSTALLATION
1. Run 10" round ductwork, from exte-
rior or in-line blower to the installation
location. For best performance, use
the straightest possible duct run and
the fewest number of elbows. Tape all
joints.
These ducting accessories are avail-
able from you dealer:
Model 410
- 10" round duct in 24"
sections
Model 421
- 10" round in-line
damper
2. Run 120 VAC electrical power cables
from service panel and exterior or in-
line blower to installation location.
3. Mount hood to wall following direc-
tions packed with hood.
TYPICAL INSTALLATION
10" Round
Duct
Studs
Nuts
Wiring
Box
Cover
Power
Cables
WIRING DIAGRAM
Refer to your hood instructions for warranty and service information.
TYPICAL IN-LINE BLOWER INSTALLATION
4. Remove wiring box cover. Remove
knockouts from the wiring box. Feed
6" of power cable through openings
and attach cables to wiring box with
appropriate connectors.
5. Align 10" round duct with collar on
mounting plate. Attach plate to studs
at top of hood with 4 nuts provided.
6. Connect wiring following the diagram
below. Connect green wires together,
then beneath the green ground screw.
Connect white wires together. To func-
tion properly, connect black wires only
as shown.