FASTEN FLUE TO HOOD AND BRACKET
WITH MOUNTING SCREWS (3,9x9,5mm)
8" ROUND
METAL DUCT
DECORATIVE
FLUE
DUCT TAPE
FLUE
MOUNTING
BRACKET
CONNECT DUCTWORK
1. Use (2) screws (4,8x38mm) and drywall
anchors to secure flue mounting bracket
to the ceiling or wall as shown.
2. Use 8" round metal duct to connect the
discharge collar on the hood to the
ductwork above.
3. Use duct tape to make all joints secure
and air tight.
4. Connect the upper flue to the bracket with
mounting screws (3,9x9,5mm).
5. Slide the lower flue downward, until it fits
properly around hood.
6. Secure lower flue to hood with mounting
screws (3,9x9,5mm).
MOUNTING
SCREWS
(4,8x38mm)
FIXING TO THE WALL
FIXING TO THE CEILING
FLUE
MOUNTING
BRACKET
MOUNTING
SCREWS