Broan E60000 Series Ventilation Hood User Manual


 
Rotate the blower and engage its
flange in the back wall retaining
bracket.
Using a 5/16” socket and the
screws previously removed, secure
the blower to the hood.
Slide the blower to disengage its flange from the
retaining bracket.
- 9 -
8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY)
HD0282
RIGHT SIDE
MOUNTING SCREW
LOCATION
All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal
discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel
of the hood. The procedure below applies for one or two blowers.
HD0270
HD0288
HD0289
Using a 5/16” socket, remove all
blower mounting screws from the
inner top of the hood. Keep the
screws for further use.
RIGHT SIDE
MOUNTING SCREW
LOCATION
LEFT SIDE MOUNTING
SCREW LOCATION
HD0269
LEFT SIDE MOUNTING
SCREW LOCATION