OPERATION
Controls
The hood is operated using the (5) push-but-
tons located at eye-level, on the front edge of
the hood.
The light switch turns the halogen lights on
and off. Push the light switch once to turn the
lights ON - push a second time to turn the
lights ON to a brighter level - push a third time
to turn the lights OFF.
The blower on-off / speed 1 switch turns the
blower on to its lowest running speed. To turn OFF the blower, push in and hold
this blower switch for approximately 2 seconds.
The blower speed 2 switch turns the blower on to medium-low running speed.
Pressing this switch a second time sets a timer which keeps the blower operating
at this speed for 10 minutes. The LED will blink during this time and the blower will
shut off automatically.
The blower speed 3 and blower speed 4 switches operate the same as blower
speed 2 switch except: Blower speed 3 is medium-high and blower speed 4 is
high.
After every 30 hours of operation, the LED above the “blower speed 1 switch” will
be illuminated (RED) and blink for 30 seconds after turning off the blower. This is
a reminder to clean the grease filters. Once the grease filters are cleaned and
installed, press in and hold the “light switch” button for approximately 2 seconds
during the blink of the LED.
BLOWER
ON-OFF /
SPEED 1
0-1
23
4
LED LED
LED
LED
BLOWER
SPEED 4
LIGHT
SWITCH
BLOWER
SPEED 2
BLOWER
SPEED 3
HALOGEN BULBS
This range hood requires four (4) halogen
bulbs (Type MR16, 12V, 20W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Loosen the ring nut by turning it
counterclockwise.
2. Pull the bulb downwards to remove - DO
NOT ROTATE. CAUTION: BULB MAY BE
HOT!
3. Replace with Type MR16, 12 volt, 20 watt
halogen bulb.
IN CASE THE NEW HALOGEN BULB DOES
NOT LIGHT UP ONCE IT IS ON, CALL FOR
SERVICE.
BULB
RING NUT