Broan K3139 Ventilation Hood User Manual


 
- 10 -
OPERATION
Controls
The hood is operated using the (4) push-
buttons located at eye-level, on the front edge
of the hood.
The light switch turns the halogen lamps on
and off.
The blower on-low / off switch turns the blower
on to its lowest running speed. The blower must
be turned on using this switch. Turn the blower
off by pressing this switch a second time.
The blower medium speed switch changes the blower speed to medium. This
switch works only if the blower is already running at low or high speed.
The blower high speed switch changes the blower speed to high. This switch works
only if the blower is already running at low or medium speed.
The pilot lamp lights up whenever the blower is on.
LIGHT
SWITCH
BLOWER
ON-LOW /
OFF
SWITCH
PILOT
LAMP
BLOWER
MEDIUM
SPEED
BLOWER
HIGH
SPEED
HALOGEN BULBS
This range hood requires two halogen bulbs
(Type T4, 12V, 20W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Loosen the ring nut by turning it
counterclockwise.
2. Remove the bulb by pulling sideward (DO
NOT ROTATE). CAUTION: BULB MAY BE
HOT!
3. Replace with Type T4, 12V, 20W halogen bulb. Do not touch replacement bulb
with bare hands!
RING NUT
FUSE REPLACEMENT
SWITCH OFF THE ELECTRICITY SUPPLY.
Remove the grease filters.
Remove the electrical box support and open
the fuse box.
Replace with the same type of fuse (5x20mm,
4A, 125V).
ELECTRICAL
BOX
SUPPORT
FUSE