INSTALL HOOD
KEYHOLE
(4)
MOUNTING
SCREW
(4)
1 Hang hood from (4) Mounting Screws (from parts bag).
Slide hood towards wall until mounting screws are engaged
in narrow end of (4) Keyholes. Tighten mounting screws
securely.
2 Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
DUCT
TAPE
CAUTION
DO NOT PUSH ON FAN BLADE. Pushing on the
blade may cause it to interfere with other hood parts.
CONNECT WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent
power from being switched on accidentally.
1 Connect House Wiring (120 VAC) to hood. Connect house
black to hood black wire, house white to hood white wire,
and house ground under Green Ground Screw. Securely
tighten cable clamp onto house wiring.
GREEN
GROUND
SCREW