INSTALL MOUNTING
BRACKET
1. Construct wood wall framing that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow the
mounting bracket to be secured to
the framing within the dimensions
shown.
2.
After wall surface is finished, secure mount-
ing bracket to framing using dimensions
shown.
FRAMING BEHIND DRYWALL
37-7/16"= bottom of hood 24"
above cooktop
43-7/16"= bottom of hood 30"
above cooktop
37-7/16” to 43-7/16”
above cooktop
INSTALL FLUE MOUNTING
BRACKET
DUCTED AND NON-DUCTED
1. Assemble the flue mounting bracket,
adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket
directly over the range hood location.
3. Secure the bracket assembly to the ceiling
using (2) 4.8x38mm mounting screws
and drywall anchors. Make sure the
bracket is pushed into the corner, tight
against the wall and centered over the
hood.
FLUE MOUNTING
BRACKET
9-13/16”
(249.8mm)
FIG. 4
3.9 x 6 mm
FLAT HEAD
BRACKET SCREWS
MOUNT THE PLATE
Mount the plate of the electrical system
attaching it with (2) mounting screws
(3.9x9.5mm).
PLATE OF
THE
ELECTRICAL
SYSTEM
MOUNTING SCREWS
(3.9x9.5mm)