Bryant ERVBBSHA Ventilation Hood User Manual


 
2
SAFETY CONSIDERAT IONS
Recognize safety information. This is the safety-- alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand
these signal words; DANGER, WARNING, and CAUTION. These
words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury
or death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify unsafe
practices which would result in minor personal injury or product
and property damage. NOTE is used to highlight suggestions
which will result in enhanced installation, reliability, or operation.
UNIT OPERATION
ERV with OneToucht Control
INTERMITTENT
MAX
MIN
A07625
Press “PUSH” until the desired ventilation operation is selected.
There are three selections: High, Low, Intermittent. The power
indicator light indicates which mode has been selected.
High This mode is recommended for the removal of excess
pollutants and humidity. The ventilator will operate at its
maximum speed continuously. The power indicator light will be lit
red when this mode is selected.
Low This mode is recommended for normal daily operation.
The ventilator will operate at its minimum speed continuously. The
power indicator light will be lit yellow when this mode is selected.
Intermittent —Thismodeisrecommendedwhentheinsideairistoo
dryintheheatingseasonortoohumidinthecoolingseason.Theven-
tilator will operate at its minimum speed for 20 minutes per hourand
be off for 40 minutes per hour. The power indicator light will be lit
green when this mode is selected.
Off— To turn the ventilator off, press “Push” until the power indica-
tor light is turned off.
ERV with Latent Control
A07621
YourERV isdesigned tooperateasan integralpartofyour totalheat-
ing and cooling system.
Low Exchange Mode—If the relative humidity inside the building
is lower than selected, air exchange would occur with the outside at
high speed. If the relative humidity level i nside the building is higher
than selected,airexchangewouldoccur outsideatlowspeed. Thisen-
sures continuous air exchange for constant air quality.
Intermittent Mode—If the relative humidity inside the building is
higher than selected, no air exchange would occur, and the system
would turn off. If the relative humidity inside the building is lower
than selected, air exchange would occur with outside at high speed.
Thismodeisidealformaintainingtheproperhumiditylevelwhenthe
continuous mode cannot.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or
death.
Before servicing system, always turn off main power to system.
Turn off accessory heater power if applicable. There may be
more than 1 disconnect switch.
!
WARNING
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges
in the construction of your unit, be extremely careful when
handling parts or reaching into the unit.
CAUTION
!
ERV