Page 8
SERVICE (cont.)
TRANSFORMER (cont.)
1 2
3
4
5
6
1 2
3
4
5
6
1
2
3 4
5
6
#6 WHI or RED From
Power Supply Connection
#6 WHI or Red to
Transformer Terminal #2
#1 BLK From Power
Supply Connection
#5 BLK to Transformer
Terminal #1
#1 BLK from Transformer
Terminal #5
#2 WHI or Red to Right
Transformer Terminal #2
#2 WHI or RED from
Transformer Terminal #6
#12 BLU/BLK to Left
Circuit Breaker
#7 BLU/BLK to Left
Rectifier "AC"
#6 WHI or RED from
Transformer Terminal #2
#12 BLU/BLK to
Right Circuit Breaker
#2 WHI or RED to
Transformer Terminal #6
#2 WHI or Red
From Left
Transformer
Terminal #2
#1 BLK to Transformer
Terminal #5
#1 BLK From Right
Transformer Terminal
#5
LEFT
RIGHT
#7 BLU/BLK to Right
Rectifier "AC"
#5 BLK from
Transformer
Terminal #1
#5 BLK to Right
Transformer Terminal #1
1
2
3
4
5
6
#6 WHI or RED from
Transformer Terminal #2
#12 BLU/BLK to
Circuit Breaker
#5 BLK From Transformer
Terminal #1
#2 WHI or RED From
Power Supply Connection
#1 BLK From Power
Supply Connection
#7BLU/BLK to Rectifier
Terminal "AC"
1SH STAND
2SH STAND
FIG.9 TRANSFORMER TERMINALS
P1404
28342 091597