Bunn 411701 Coffeemaker User Manual


 
Page 6
BREW TYPE (A/B) (Tea/Coffee)
Tea setting provides half the "purge" pressure as coffee at the end of brew
cycle.
BREW TYPE A
TEA DONE COFFEE
BREW OZ A: 8.0
(-) DONE (+)
BREW METER A: 2
- +
BREW OZ. (A/B) (1-16)
Adjust brew volume.
BREW METER (A/B) (1-5)
Simplifi ed pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
ENTER SERVICE #
Program service phone number to be displayed anytime there is a fault mes-
sage.
ENTER PASSWORD
User must enter a 3 digit number to access remainder of adjustments. If no
number has been pre-programmed (0 0 0), then access is allowed.
ENTER SERVICE #?
NO YES
ENTER PASSWORD
0 0 0
SET PASSWORD
0 0 0
SET PASSWORD (001-999)
Program any three digit number as a password.
SET LANGUAGE
Choose between English or Spanish.
UNITS
METRIC DONE ENG
SET LANGUAGE ?
NO YES
ENTER ASSET # ?
NO YES
SET TEMP: 200°
(-) DONE (+)
SET READY: 195°
(-) DONE (+)
UNITS
Choose between English (Oz, F°) or metric (Ml, C°)
SET TEMP
Adjust tank temperature 185 to 205° F (85 to 96° C)
SET READY
Sets the minimum temperature allowable to start a brew cycle, if "BrewLockout"
is enabled. Range: (2° to 20° F) or (2° to 10° C) below the set temperature.
ENTER ASSET #
This function allows the you to enter in an optional 4 digit number. This can be
useful for tracking the usage of an individual machine within a group.
PROGRAM FUNCTIONS
SET PULSE BREW (A/B)
Individually adjust on/off times. 1st on time: OFF-.5-24.0; OFF time: OFF-.5-24.0;
Last on time: Preinfusion-.5-24.0
This will overwrite "BREW METER"
SetPulseBrew A/B ?
NO DONE YES
AIR TIME (A/B) (1-25 seconds)
Time the brew tank is purged at the end of each brew cycle.
AIR TIME A/B: 15.0
(-) DONE (+)
CONTINUED
411701 061308