Heating Too Long Error Message
Model: AutoPOD™ and AutoPOD™ with Booster Pump
Common Cause(s): Heater relay on greater than 6 minutes.
Troubleshooting: Check for open element, limit thermostat and heater relay coil. If components check good, the
main control has a triac on the board that supplies the output voltage to the tank elements. Check CBA.
Repair: Replace the faulty component(s).
Prevention: N/A
Additional Notes: N/A
Motor Obstruction Error Message
Model: AutoPOD™ and AutoPOD™ with Booster Pump
Common Cause(s): Motor current increased over .55 amp great than 3 seconds.
Troubleshooting: Check for defective index motor sensor which does not see a slot in the position disc and will over
run the position slots and jam creating the error message. Another reason could be machine or ejector assembly
damage due too negligence (dropping) of the equipment, the components or ejector linkage could be out of align-
ment which relates to increased restriction in the linkage assembly during the brew and pod eject process and will
display the “Obstruction” error message.
Repair: Clean, repair, or replace the faulty component
Prevention: Be aware of the instruction on the outside of the original shipping carton. “Delicate Electrical Instru-
ment- Handle With Great Care” and this side “Up” message.
Additional Notes: N/A
Replace Seal Message
Common Cause(s): Machine has exceeded the allowable brews and will display “Replace Seal” message.
Troubleshooting: N/A
Repair: Replace sprayhead seal and enter program and answer “Yes” to the “Seal Replaced” menu to reset brew
count for next countdown.
Prevention: Perform recommended cleaning of the sprayhead and seal to keep it from prematurely wearing before
warning “replace seal” message appears.
Additional Notes: N/A
Rev. 06/26/09