Page 28
SERVICE (cont.)
DISPENSE VALVE
Location:
The dispense valve is located inside the top cover
behind the front end cap.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Check the water level in the tank to confirm that it
is within 1/2" from the top of the tank.
3. Connect the brewer to the power source. If the
brewer has been set for brewer temperature lock-
out, this feature must be disabled. See Page 8 for
procedure.
4. Check the dispense valve for coil action. Place the
ON/OFF switch in the "ON" position, press and
release the BREW switch. Listen carefully in the
vicinity of the dispense valve for a "clicking" sound
as the coil magnet attracts and repels the plunger.
5. Disconnect the brewer from the power source.
If the sound is heard as described, there may be a
blockage in the dispense valve or the water line to the
sprayhead. Remove the dispense valve and inspect for
wear, and remove waterborne particles.
If the sound is not heard as described, proceed to #6.
P1852
P1853
WHI/GRN from
Control Board
WHI from Terminal
Block
FIG. 10 DISPENSE VALVE WIRING
C
A
U
T
IO
N
:
WARMERS AND SURFACES ARE HOT