Bunn TCD-1 Beverage Dispenser User Manual


 
INTRODUCTION
These dispensers are designed to mix liquid tea concentrate with water to produce iced tea by the glass or pitcher. The
concentrate can be stored either inside the dispenser, or outside with a hose connection to the dispenser. The dispenser
must be placed on a sturdy counter or shelf.
3
34106.1 060706
PLUMBING REQUIREMENTS
This dispenser must be connected to a cold water system with operating pressure between 30 and 90 psi
(138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the
dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi
(345 kPa). The water inlet fitting is 1/4" flare.
NOTE - Bunn-O-Matic recommends 1/4" copper (or 3/8" braided flex) tubing for all installations from the 1⁄2"
water supply line. A tight coil of copper tubing in the water line will facilitate moving the dispenser to clean the
counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and
shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials
and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the
Food and Drug Administration (FDA). For models installed outside the U.S.A., you must comply
with the applicable Plumbing/Sanitation Code for your area.
This equipment must be installed to comply with the
Basic Plumbing Code of the Building Officials and
Code Administrators International, Inc. (BOCA) and
the Food Service Sanitation Manual of the Food and
Drug Administration (FDA). For models installed
outside the U.S.A., comply with the applicable
Plumbing /SanitationCode.
USER NOTICES
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.
00656.0000
38130.0000
PRESSURE REGULATOR ADJUSTMENT
1. Pull Knob out to unlock.
2. Adjust to 20 psi while faucet
is open, dispensing product.
3. Push knob in to lock.
38465.0000
C
L
O
S
E
O
P
E
N
38466.0000