Page 18
SERVICE (cont.)
TL1 - WHI to Power Cord (100V & 120V) or
RED to Power Connector (230V) and
WHI to On/Off Switch (100V & 120V) or
RED to On/Off Switch (230V)
TL2 - WHI/VIO to Brew Solenoid and
WHI/VIO to On/Off Switch
TL3 - WHI/ORN to Start Switch
TL4 - WHI/GRN to Brew Solenoid
TL5 - WHI/YEL to Start Switch
FIG. 7 DIGITAL TIMER WIRING
P2037
DIGITAL BREW TIMER (Late Models) (cont.)
10288 071000
To increase a brew volume, place the ON/OFF
switch in the “ON” position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory.) Each
time the switch is pressed, two seconds are added to
the brew time period. Allow the brew cycle to finish in
order to verify that the desired volume has been
achieved.
To decrease a brew volume, place the ON/OFF
switch in the “ON” position, press and release the
START switch once for every two-second interval to
be removed from the total brew time period; then im-
mediately press and hold down the START switch until
three clicks are heard. Release the switch. (Failure to
release the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory). Allow
the brew cycle to finish in order to verify that the de-
sired volume has been achieved.
2. Setting brew volumes. To set a brew volume, first
check that the SET/LOCK switch is in the “SET” posi-
tion on the circuit board. Place the ON/OFF switch in
the “ON” position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release the switch within two
seconds after the third click causes the volume set-
ting to be aborted and previous volume setting will
remain in memory.)
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to “OFF”.
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch “OFF”.
The brewer remembers this volume and will continue
to brew batches of this size until the volume setting
procedure is repeated.
NOTE: When brewing coffee, volume will decrease due
to absorption by the coffee grounds.
3. Setting programming disable feature. If it becomes
necessary to prevent anyone from changing brew time
once programmed, you can set the SET/LOCK switch
to the “LOCK” position. This will prevent any further
programming until switch is once again put into the
“SET” position.