6
1
3
PROGRAMMING
Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify
various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also
prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also
the opportunity to return all changes back to factory default settings.
Access to most controls can be password protected to allow only qualified personnel to make changes.
2
PROGRAMMING SWITCHES
To access the programming mode, and to scroll through the different function screens, hidden programming
switches are used. There are three of these switches that will be used for the setup of the dispenser.
1. I/O switch (upper left corner of the control pad)
This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. This switch is
also used as back up switch in menu mode.
2. “GOURMET” (center under display)
Press and hold this switch 5 seconds to access the Menu Function Index. This switch is also used as “NEXT”
to scroll through the functions.
3. “ULTRA” (left under display)
When prompted by a selection from the menu to answer yes or no, the “ULTRA” switch is used to answer
“NO” or (-) minus.
4. “ICE” (right under display)
When prompted by a selection from the menu to answer yes or no, the “ICE” switch is used to answer “YES”
or (+) plus.
P3677
4
1
4
3
2
P3931
ULTRA-1
ULTRA-2
41047 040108