OPERATIONAL CHECKS
27
ELECTRICAL INSTALLATION
WARNING - THIS APPLIANCE MUST BE EARTHED
The cooker must be connected by a qualified electrician to a suitable double - pole control
unit with a minimum rating of 32A and a minimum contact clearance of 3mm, which
should be fitted adjacent to (but not above) the cooker, in accordance with IEE
regulations.
The power supply cable should conform to BS6004 with a conductor size of 4mm
2
.
The control unit should be easily accessible in the event of an emergency.
This appliance conforms to EN55014 regarding suppression of radio and television
interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp adjacent to the terminal block, and
the screws must be fully tightened. Sufficient cable should be used to allow the cooker to
be pulled out for servicing.
Take care not to trap the mains cable when pushing the cooker into its final position.
CONVERSION FOR USE WITH LPG
Referring to the chart on page 24, remove the natural gas injectors and replace with
those for LPG from the conversion kit provided. Remove the hotplate control knobs and
using a long narrow flat bladed screwdriver, turn the bypass screw located down the
centre of each control spindle, fully clockwise.
Secure the label supplied with the kit, over the relevant part of the data badge to show the
new adjustment conditions.
After installation, check for gas soundness.The supply pressure can be checked at one of
the hotplate burner injectors.
Check that the hotplate burners ignite correctly and burn with a steady flame. Check for a
steady flame at the low setting.
Instruct the user on the operation of the cooker.
INSTALLATION INSTRUCTIONS