Natural Gas L.P.G.
19
INSTALLATION INSTRUCTIONS
HEAT INPUT INJECTOR HEAT INPUT INJECTORBURNER
3.3 kW (240g/h)GRILL
2.4 kW (175g/h)
OVEN
2.8 kW (205g/h)HOTPLATE
Front left and rear right
1.8 kW (130g/h)
91
72
82
65
3.9 kW
2.5 kW
3.0 kW
1.9 kW
135
115
128
102
HOTPLATE
Front right and rear left
TECHNICAL DATA
DIMENSIONS
Height to hotplate 895 - 910mm
Height overall 900 - 915mm
Width 538mm
Depth 600mm (excluding door handles and control knobs).
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
” BSP female)
Pressure test point Grill injector
Gas rate adjustment None
Aeration adjustment None
Battery 1.5V Alkaline AA